Difference Between MPO and MTP® Connectors

Question:  What is the difference between MPO and MTP® Connectors? Answer: MPO (Multi-Position Optical) and MTP® (Multifiber Termination Push-on) Connectors are essentially the same, with MTP® being a branded version of MPO. Both are designed for ribbon...
Read More

SC Connector Single-Mode and Multi-Mode Configurations

Question:  Is the SC Connector available in both single-mode and multi-mode configurations? Answer: Yes, the SC Connector is available in both single-mode and multi-mode configurations. The SC features a square shape, a 2.5mm ferrule compatible with FC and ST...
Read More

SC Connectors Interface Standards

Question: Where are the SC Connector's interface standards outlined? Answer: The SC Connector's interface standards are outlined in IEC 61754-4 and TIA-604-3 and end face geometry in IEC 61755-3-1. This connector's development paralleled the introduction of PC...
Read More

Key Features of LC Connectors

Question: What are the key features of LC Connectors? Answer: Some of the key features of LC Connectors include:  A small form-factor ideal for high-density applications. Compatibility with both single-mode and multimode optical fiber. Low...
Read More

History of the LC Connector

Question: Who developed the first LC Connectors and are they the same design now? Answer: LC Connectors, also known as Lucent Connectors, are also referred to as “Little Connector” or “Local Connector”, were developed by Lucent Technologies in 1994 as a...
Read More

Assembly Requirement Differences Between LC Connectors and SC Connectors

Question: Is the assembly of LC Connectors the same as SC Connectors or does it require different equipment? Answer: Assembly of the LC Connector mirrors that of SC Connector, though it requires specific equipment and processes due to the 1.25mm ferrule...
Read More

SC Connectors Preferred Applications

Question: What applications are SC Connectors preferred for? Answer: These connectors are favored for their cost-effectiveness and push-pull mechanism, particularly in Passive Optical Networks (PONs), converters, and telecom applications, often using APC...
Read More

Ceramic Ferrules in FC Connectors

Question: What is the first connector to have a ceramic ferrule? Answer: FC Connectors were the first to feature a ceramic ferrule. They are compatible with other connector types like SC and ST, typically featuring stainless steel or plastic bodies. For additional...
Read More

ST Connector Polishing and Rework Guidelines

Question:  How many times can you run an ST Connector before the connector is no good. I have run STs three times and am still having a scratch issue. Thoughts? Answer: If you have polished off the entire chamfer of the ferrule, you have polished too much....
Read More

MPO/MTP® Connectors in Data Centers

Question:  Are MPO/MTP® connectors the best for data centers and why? Answer: MPO/MTP® Connectors support 12 to 32 fiber counts, crucial for high-density network cabling systems, facilitating 40G and 100G parallel lane connectivity. MTP® Connectors...
Read More